Surface Calculation Failures and Workarounds

Molecular surface calculations in Chimera (surface command, Actions... Surface... show in the menu) use the MSMS package and are subject to sporadic numerical failure. These failures are not very predictable, except for a tendency to occur more frequently for larger structures. Most failures are on structures with >10,000 atoms, and on the largest (~50,000 atoms), it may not be possible to find settings that allow successful calculation of the molecular surface (but see alternatives). Failures may even vary from platform to platform, with one computer failing but another successfully generating the molecular surface of the same structure using the same parameters, due to small differences in rounding. Surface calculation fails more often on Windows than on Mac and Linux, and more often in the 64-bit Windows version of Chimera than in the 32-bit Windows version.

Unfortunately, how to avoid a failure is also not very predictable, but anything that affects the surface shape (even quite subtly) may suffice.

The first thing to consider is whether the surface calculation has failed completely, or whether the main component (generally enclosing the structure) has been generated successfully and the failure only affects the smaller components (generally interior bubbles). If the surface of interest is shown and other components are not needed for display or calculations, surface calculation error messages can be ignored. It is possible, however, for the calculation to proceed without error messages but still generate localized defects such as interior bubbles poking through the outer surface.

Workarounds

  1. Subdividing the problem. The first two approaches involve breaking the problem into parts to simplify the calculation:

  2. Adjusting molecular surface parameters. The next set of approaches subtly change the surface shape or triangulation process without changing the set of atoms to be enclosed:


  3. Alternative kinds of surfaces. The last two possibilities generate surfaces that are not exactly the (solvent-excluded) molecular surface, but may suffice for visualization:


    Like molecular surfaces, these alternative surfaces can be colored to match the underlying atoms (see Color Zone and msc) or to show associated data such as electrostatic potential (see Surface Color and coulombic with the atoms option).

  4. CPK representation. Displaying all atoms as VDW spheres also gives a space-filling representation of the molecule, albeit not smoothed like a surface. For example, commands:
    ~ribbon
    show protein
    repr sphere protein
    color tan